INSPECTION TYPE: 3C, LONGERON 9L SPLICE FITTING CRACKED AT BS 1531. REMOVED, FABRICATED, AND INSTALLED A REPLACEMENT LONGERON SPLICE IAW DWG A5A7112, AND SRM 51-33-01.