What was found
INSPECTION TYPE:C12, CORROSION ON NUT PLATE (P/N:BACN10JR3CFD) OF M/D CGO FLOOR STRUCTURE AT STA 1598-STA 1603, LBL 12-LBL 23. REPAIR IAW SRM 51-40-02-0G REV71.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C12, CORROSION ON NUT PLATE (P/N:BACN10JR3CFD) OF M/D CGO FLOOR STRUCTURE AT STA 1598-STA 1603, LBL 12-LBL 23. REPAIR IAW SRM 51-40-02-0G REV71.