What was found
INSPECTION TYPE:C1, FUSELAGE KEELBEAM MANHOLE DOUBLER FROM STA 810-840 FOUND CORROSION. REMOVED DOUBLER AND ANGLE NUT PN: BACN10JN3 FOR ACCESS CORROSION BLENDED OUT REWORK AREA SMOOTHEN SIZE OF RWK L=1.0"X W=0'5" ORIGINAL THK =0'080" MATERIAL REMOVED =0'003" REMAIN THK =0'077" 10X DVI CARRIED OUT SURFACE SCAN AND OPEN HOLES INSPECTION CARRIED OUT PER NDTM 51-00-19 AND 51-00-16 PART 6 NO CRACK EVIDENT. RWK AREA REPROTECTED