What was found
DURING LEVEL OFF AT FL 320, RECEIVED A FORWARD ENTRY DOOR NOT CLOSED, RED LIGHT IN THE SLIDE LEVER AREA, AND HORN. THE RIGHT DOOR CLOSED INDICATOR SHOWED 1/2 GREEN AND 1/2 RED. PUSHED HANDLE CLOSED, HORN AND LIGHT EXTINGUISHED. CYCLED THE DOOR SEVERAL TIMES IAW AMM 52-10-20, PG 501, PARA 2C [1], TESTED OK. CHECKED SEALS, LATCHES AND ROLLERS, OPS NORMAL. OK FOR SERVICE.