What was found
DURING PREFLIGHT, THE EMERGENCY EXIT LIGHT AT THE CABIN DOOR WAS FOUND DETACHED FROM THE HOUSING BRACKET. ATTACHED THE LIGHT IAW SRM 51-30-10-OG
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING PREFLIGHT, THE EMERGENCY EXIT LIGHT AT THE CABIN DOOR WAS FOUND DETACHED FROM THE HOUSING BRACKET. ATTACHED THE LIGHT IAW SRM 51-30-10-OG