What was found
EMERGENCY EXIT SIGN DID NOT ILLUMINATE & WAS CRACKED. REPLACED EMERGENCY EXIT SIGN ASSEMBLY IAW AMM 33-51-01-022-029, & 31-51-01-402-030. REPLACED THE POWER SUPPLY IAW 33-51-00, & CONTROL RELAY IAW 33-51-11, OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY EXIT SIGN DID NOT ILLUMINATE & WAS CRACKED. REPLACED EMERGENCY EXIT SIGN ASSEMBLY IAW AMM 33-51-01-022-029, & 31-51-01-402-030. REPLACED THE POWER SUPPLY IAW 33-51-00, & CONTROL RELAY IAW 33-51-11, OPS CHECKED GOOD.