What was found
COMPT & CMP UNCONTROLLABLE 60-83, FLT DECK, FWD CAD, AFT CABIN, TEMP 00/54/50. AUTO C FULL WARNING ON STBY N TEMP 60/54/50 ON W TEMP 58/52/50. REMOVED & REPLACED ZONE TEMP CONTOLLER IAW AMM 21-63-03-0401. PERFORMED SYSTEM TEST, PRIMARY ZONE TEMP CONTROLLER IAW AMM 21-61-00-705-030. ZONE TEMP SYSTEM CHECKED GOOD IAW 21-61-00-01.