Service difficulty report · Oil System · Doug MD11F

Difficulty date
November 8, 2018
Submitted
November 9, 2018
Operation
Air carrier
Aircraft
N274UP
Make and model
Doug MD11F
Aircraft serial
48575
Aircraft time
69,409 hours, 13,212 cycles
Part
Oil System
Condition
Leaking
Location
Apu
Stage of operation
CL
How discovered
O
Nature of condition
K, B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

STRONG ODOR IN THE COCKPIT. THE ODOR THAT WAS PREVIOUSLY TROUBLESHOT, CAME BACK STRONG DURING CLIMB OUT, CAUSED BURNING EYES, THROAT, LUNGS. COMPLIED WITH AIR CONDITONING PACKS AND DUCTS, RUNNING APU FOR 1.5 HOURS, OIL QUANTITY WAS 8.0, AFTER 1.5 HOURS, THE APU OIL QTY WAS 5.5, NO EXTRA ROLLERS FOUND. ODOR IN THE ACFT WAS DUE TO OIL LOSS.

More about the Doug MD-11F