What was found
INSPECTION TYPE: 4C, CENTER CARGO FLOOR SUPPORT RETAINER WAS CRACKED AT BS 1521. REMOVED, FABRICATED, AND REPLACED THE RETAINER IAW DWG AEA0341, AND SRM 51-35-01. MINOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: 4C, CENTER CARGO FLOOR SUPPORT RETAINER WAS CRACKED AT BS 1521. REMOVED, FABRICATED, AND REPLACED THE RETAINER IAW DWG AEA0341, AND SRM 51-35-01. MINOR.