What was found
INSPECTION TYPE:4CJACK PAD IS GOUGED IN 3EA LOCATIONS.REMOVED DOUBLER AT JACK PAD AND REMOVED DOUBLER FORWARD OF JACK PAD, EXTERNAL CUTOUT AND INCORPORATED THE TWO REPAIRS,FABRICATED FILLERS, DOUBLER AND INSTALLED IAW A300-600 SRM 53-10-12, PAR.13, FIG.210.