What was found
INSPECTION TYPE:2C STA. 6-70 ABOVE LONGERON 43L, FLOORBEAM IS CRACKED. REPAIRED CRACKED FLOORBEAM AT STA. 6-70, X=57.5 AND Z=-98 IAW SRM 53-40-51 REPAIR 1 FIG. 201. (MAJOR)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:2C STA. 6-70 ABOVE LONGERON 43L, FLOORBEAM IS CRACKED. REPAIRED CRACKED FLOORBEAM AT STA. 6-70, X=57.5 AND Z=-98 IAW SRM 53-40-51 REPAIR 1 FIG. 201. (MAJOR)