What was found
INSPECTION TYPE:124C AFT PIT, BULK CARGO, LOWER STEP UP WALL, FRAME 69 LEFT VERTICAL WEB IS DENTED NUMEROUS SPOTS. REMOVED AND REPLACED VERTICAL WEB IAW SRM 51-40-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:124C AFT PIT, BULK CARGO, LOWER STEP UP WALL, FRAME 69 LEFT VERTICAL WEB IS DENTED NUMEROUS SPOTS. REMOVED AND REPLACED VERTICAL WEB IAW SRM 51-40-21.