What was found
INSPECTION TYPE:N/AEMER LT BAT 1 LO ANNUNCIATED ON PREFLIGHT. DEFERRED PER MEL # 33-50-2 DMI # M667365 ASSIGNED DMP 33-50-2 CW PLACARD INSTALLED OK FOR SERVICE.T/S PER FIM 33-51-00-101 FIG 104 BLOCKS 1, 2, 6, & 7. FOUND "EMER LT BAT 01 LO" R/R BATTERY POWER SUPPLY PER MM 33-51-01. OPS CK GOOD. THIS CLEARS M667365