As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:N/A R1 DOOR ELECTRIC OPERATION INTERMITTENT FROM EITHER SWITCH. DEFERRED R1 DOOR ELECTRIC OPERATION INOP PER MEL 52-10-1-2-0-1 ON M668612. DMP C/W. **SUPPLEMENTAL SDR** REPLACED UP LIMIT SWITCH PER SWPM 20-30-00 ( 51-592) AND REPLACED ELECTRIC DOOR ACTUATOR M1-71 PER MM 52-11-01-401. DOOR OPS CKS GOOD PER MM 52-11-02-830-805 M668612. CLEARED ESR: IPC 52-11-70-01-080 AND 52-11-05-05-525.