What was found
INSPECTION TYPE:SDR RT INBD FLAP LEADING EDGE DAMAGE (DENTED). ACCOMPLISHED INTERIM MINOR REPAIR PER EO A300-5750-92544A 05577896 5-9-19/ AS PER EO A300-5750-72544A, ACCOMPLISHED HFEC PER NDTM / PART 6,51-00-08 AND HFEC ILLEG SCAN PER NDSM PART 6, 51-10-01 NO CRACKS NOTED. ACCOMPLISHED ULTRASOUND THICKNESS CHECK. AIRCRAFT OK FOR SERVICE.