What was found
INSPECTION TYPE:2CR/H MLG W/W O/B FWD. DOOR CUT-OUT WEB/RIB IS CRACKED.REMOVED, FABRICATED AND REPLACED WEB/RIB IAW DWG. ANB7180 AND SRM 51-35-01. (MINOR)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:2CR/H MLG W/W O/B FWD. DOOR CUT-OUT WEB/RIB IS CRACKED.REMOVED, FABRICATED AND REPLACED WEB/RIB IAW DWG. ANB7180 AND SRM 51-35-01. (MINOR)