What was found
INSPECTION TYPE: 2C, CENTER CARGO COMP. L/H PANEL LANDING IS CRACKED AT STA. 1661.REMOVED, FABRICATED AND REPLACED ANGLE ISW DWG. ADA0130 AND SRM 51-31-01. (MINOR)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: 2C, CENTER CARGO COMP. L/H PANEL LANDING IS CRACKED AT STA. 1661.REMOVED, FABRICATED AND REPLACED ANGLE ISW DWG. ADA0130 AND SRM 51-31-01. (MINOR)