What was found
EMERGENCY DECLARED, SLAT AND FLAP FAULT SYS 1 AND 2 ILLUMINATED ON EXTENSION FROM F20 TO F40. FOLLOWED ECAM PROCEDURE AND SELECTED F40 WITH NO FURTHER FAULTS. PERFORMED BITE TEST IAW TSM 27-50-00, NO DEFECTS NOTED. AIRCRAFT OK FOR SERVICE.