Service difficulty report · Flap System · Airbus A300F4622R

Difficulty date
August 14, 2019
Submitted
August 14, 2019
Operation
Air carrier
Aircraft
N147UP
Make and model
Airbus A300F4622R
Aircraft serial
0830
Aircraft time
18,454 hours, 11,803 cycles
Part
Flap System
Condition
Faulted
Location
Flaps & Slats
Stage of operation
AP
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

EMERGENCY DECLARED, SLAT AND FLAP FAULT SYS 1 AND 2 ILLUMINATED ON EXTENSION FROM F20 TO F40. FOLLOWED ECAM PROCEDURE AND SELECTED F40 WITH NO FURTHER FAULTS. PERFORMED BITE TEST IAW TSM 27-50-00, NO DEFECTS NOTED. AIRCRAFT OK FOR SERVICE.