What was found
INSPECTION TYPE:2CCENTER CARGO LONGERON 30R IS CRACKED BETWEEN STA. 1641-1651.REPAIRED CRACKED CENTER CARGO LONGERON 30R BETWEEN STA. 1641-1681 IAW SRM 53-00-05 REPAIR 1 FIG. 201 & 202. (MAJOR)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:2CCENTER CARGO LONGERON 30R IS CRACKED BETWEEN STA. 1641-1651.REPAIRED CRACKED CENTER CARGO LONGERON 30R BETWEEN STA. 1641-1681 IAW SRM 53-00-05 REPAIR 1 FIG. 201 & 202. (MAJOR)