What was found
INSPECTION TYPE:N/AL FWD ENTRY DOOR EICAS ILLUMINATED DURING TAKE OFF THEN EXTINGUISHED @500 FEETPER FIM 52-90-01-44 AMM TASK 52-71-00-735-053 DOOR SYSTEM TEST NO FAULTS NOTED AT THIS TIME OK TO CONTINUE
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:N/AL FWD ENTRY DOOR EICAS ILLUMINATED DURING TAKE OFF THEN EXTINGUISHED @500 FEETPER FIM 52-90-01-44 AMM TASK 52-71-00-735-053 DOOR SYSTEM TEST NO FAULTS NOTED AT THIS TIME OK TO CONTINUE