As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ENTRY DOOR HAS PRESSURE LEAK. DURING CLIMB AND DESCENT ABOUT 2-3 CABIN DIFF.CABIN PRESS LEAK TEST PERFORMED IAW AMM 05-51-24-201 REV 128.03 FOUND LEAK AT LOWER DOOR AREA AND SCUFF PLATE NOT SUFFICIENT SEALED. SCUFFPLATE CELANED AND NEW SEALANT APPLIED IAW AMM 51-31-01-201 REV 128.03. AFTER CURE TIME OF SEALANT PERFORMED LEAK TEST IAW AMM 05-51-24-201