What was found
INSPECTION TYPE:300AFT CABIN FRAME 79 R/H SIDE AT FLOOR CUSP; SHEAR WEB CRACKED THROUGH THE LIGHTNING HOLE.RP 02285 REMOVED CRACKED SHEAR WEB RH 02285, LOCATED AND DRILLED NEW SHEAR WEB, INSTALLED
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:300AFT CABIN FRAME 79 R/H SIDE AT FLOOR CUSP; SHEAR WEB CRACKED THROUGH THE LIGHTNING HOLE.RP 02285 REMOVED CRACKED SHEAR WEB RH 02285, LOCATED AND DRILLED NEW SHEAR WEB, INSTALLED