What was found
INSPECTION TYPE:2C CENTER CARGO LONGERON 44R HAS CORROSION AT STA 1611. REPAIRED CORRODED LONGERON 44R BETWEEN STA 1610 TO 1632 IAW SRM 53-00-05 REPAIR 1 FIG 201. (MAJOR)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:2C CENTER CARGO LONGERON 44R HAS CORROSION AT STA 1611. REPAIRED CORRODED LONGERON 44R BETWEEN STA 1610 TO 1632 IAW SRM 53-00-05 REPAIR 1 FIG 201. (MAJOR)