INSPECTION TYPE:2C, FWD CARGO L/H STA 6-70 FLOOR BEAM ANGLE BRACKET CRACKED. REMOVED, FABBED AND INSTALLED FLOOR BEAM ANGLE BRACKET IAW SRM51-31-01 AND DRAWING ADA3645