What was found
INSPECTION TYPE:N/A** ATB ** EMERGENCY DECLARED**LANDED WITHOUT INCIDENT ** AT APROX 8000' RIGHT ENGINE EGT SURGE TO ABOUT 890 DEG . APPROX TIME OF 5 SEC. JUMP SEATER STATED HE SMELLED AND ODER AT TIME OF EVENT AFTER REDUCING POWER TO REDUCE EGT INTO NORMAL RANGE EPR FELL BELOW BASE LINE TO APPROX .90.REF L/PS 290864/1 & 290865/1 FOUND DIRT/DEBRIS LODGED P1 TUBE. CLEANED DEBRIS & FLUSHED LINE WITH DRY NITROGEN IAW FIM 73-21-00-301, 71-05-00-815-824-ROO & 71-05-00-815-819-ROO. PERF'D PWR PLANT TEST 11 & 13 PER MM 71-00-00-715-197-RO3 3. ALL PARAMETERS NORMAL. A/C OK TO CONTINUE SERVICE. NO DMG TO RT ENG.