What was found
INSPECTION TYPE: 2C MAIN CABIN FLOOR PANEL IS CORRODED BETWEEN STA X= -8.5 TO -27.5 AND Y=392-440. REMOVED, FABRICATED, AND REPLACED FLOOR PANEL IAW DWG WSP0668 AND SRM 51-33-01 (MINOR).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: 2C MAIN CABIN FLOOR PANEL IS CORRODED BETWEEN STA X= -8.5 TO -27.5 AND Y=392-440. REMOVED, FABRICATED, AND REPLACED FLOOR PANEL IAW DWG WSP0668 AND SRM 51-33-01 (MINOR).