What was found
INSPECTION TYPE: 2C L-3 DOOR JAMB LOWER AFT WEB IS CRACKED AT STA 1307 AND Z= -18. REPAIRED CRACKED L-3 DOOR JAMB LOWER AFT WEB AT STA 1307 AND Z= -18, IAW SRM 53-40-15 REPAIR 3 FIG. 201 (MAJOR).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: 2C L-3 DOOR JAMB LOWER AFT WEB IS CRACKED AT STA 1307 AND Z= -18. REPAIRED CRACKED L-3 DOOR JAMB LOWER AFT WEB AT STA 1307 AND Z= -18, IAW SRM 53-40-15 REPAIR 3 FIG. 201 (MAJOR).