What was found
INSPECTION TYPE: 3C MAIN CABIN FLOOR SUPPORT IS CORRODED AT STA 1481 AND LBL 48. REMOVED, FABRICATED, AND REPLACED FLOOR SUPPORT, IAW DWG ACA3763 AND SRM 51-35-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: 3C MAIN CABIN FLOOR SUPPORT IS CORRODED AT STA 1481 AND LBL 48. REMOVED, FABRICATED, AND REPLACED FLOOR SUPPORT, IAW DWG ACA3763 AND SRM 51-35-01.