What was found
INSPECTION TYPE: N/A ALERT (INT) DOOR F/D OVERHEAD EICAS MESSAGE DISPLAYED TECH RECOMMENDS. R & R S2312 SW WAN 3189233. REMOVED AND REPLACED OVERHEAD HATCH DOOR WARNING SWITCH S2312, PER AMM 52-71-01. OPERATIONS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: N/A ALERT (INT) DOOR F/D OVERHEAD EICAS MESSAGE DISPLAYED TECH RECOMMENDS. R & R S2312 SW WAN 3189233. REMOVED AND REPLACED OVERHEAD HATCH DOOR WARNING SWITCH S2312, PER AMM 52-71-01. OPERATIONS CHECK GOOD.