What was found
INSPECTION TYPE: 2C FWD CARGO CEILING LINER SUPPORT CHANNEL BENT AND HAS 3 EA FASTENER HOLES CRACKED BETWEEN STA 899-999 X= -65.5. REPLACED SUPPORT CHANNEL ON FWD CARGO CEILING AT STA 899-999 X= -65.5, IAW SRM 51-35-01. (MINOR)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: 2C FWD CARGO CEILING LINER SUPPORT CHANNEL BENT AND HAS 3 EA FASTENER HOLES CRACKED BETWEEN STA 899-999 X= -65.5. REPLACED SUPPORT CHANNEL ON FWD CARGO CEILING AT STA 899-999 X= -65.5, IAW SRM 51-35-01. (MINOR)