As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE: N/A F/O'S DOME LIGHT DOESN'T REMAIN ON WHEN TESTING EMERGENCY PROCEDURE BY PULLING C/B 57LE. TROUBLESHOT USING ASM 33-12-00 AND FOUND EMERGENCY LIGHTING SWITCHING RELAY (43LE) TO BE BAD. REMOVED AND REPLACED 43LE RELAY, IAW ESPM 20-46-50. OPERATIONS TEST GOOD, OK FOR SERVICE.