As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE: 4C VERTICAL STAB NR 2 PYLON WEB ANGLE IS CRACKED JUST AFT OF NR 4 BANJO FITTING INSIDE PANEL 457AL. REPLACED CRACKED VERTICAL STAB NR 2 PYLON WEB ANGLE JUST AFT OF NR 4 BANJO FITTING INSIDE PANEL 457AL, IAW MD-11 SRM 54-05-41. (MINOR)