What was found
INSPECTION TYPE: NA WHILE PERFORMING PMC 19, NOTICED BROKEN PROXIMITY SWITCH S00194 ON MAIN ENTRY DOOR. REMOVED AND INSTALLED NEW PROXIMITY SWITCH S00194 P/N OFF: 8-345-03, S/N OFF: A103867, P/N ON: 8-935-01, S/N ON: A53402, PER AMM CH: 52-71-01-964-211 AND CH: 20-55-54-816-016. REGGING CHECKED GOOD. IPC CH: 52-71-01-10C FIG NR A ITEM NR 15.