Service difficulty report · Relay · Airbus A300F4622R

Difficulty date
December 10, 2020
Submitted
December 11, 2020
Operation
Air carrier
Aircraft
N141UP
Make and model
Airbus A300F4622R
Aircraft serial
0824
Aircraft time
21,482 hours, 13,519 cycles
Part
Relay
Condition
Failed
Location
Nr 2 A/C Pack
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

INSPECTION TYPE: NA DIVERSION-NO EMERGENCY DECLARED-AC TAKEN OUT OF SERVICE. CLIMBING THROUGH FL 270 RECEIVED PACK 2 FAULT. ECAM DIRECTED US TO TURN PACK 1 ON, PACK 1 FAILED SHORTLY AFTER SELECTING IT ON. UNABLE TO REGAIN EITHER PACK, ECAM DIRECTED US TO DESCEND MAX ALTITUDUE OF 10,000 PER TECH SUPPORT FLT RECORDER INTEROGATION FOUND APU BLEED VALVE OPEN. WITH NO ENGINE BLEED TO PACKS. REMOVED AND REPLACED APU VALVE CONTROL RELAY, PER ASM 36-12-00 AND ESPM 20-46-50. ACCOMPLISHED APU BLEED TEST, PER 36-12-00 PG 501 AND ENGINE BLEED TEST, PER 36-11-00.