What was found
INSPECTION TYPE: NA CREW ENTRANCE DOOR UNLOCK (LIGHT OUT AT FL180 ON DESCENT) FLASHING WITH AURAL TONE UPON CLIMBOUT PASSING FL 300 ECAM INDICATIONS NORMAL AND ALL OTHER PRESSURATION INDCATIONS NORMAL. ADJUSTED SWITCH 9 WN, REF A300 600 ASM 52 73 00 AND AMM 52 73 13 0501. TEST GOOD, PER AMM 52 73 13 0501, OKAY TO CONTIINUE.