As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
L1 ENTRY DOOR ACTUATOR INOP. DEFERRED L1 ENTRY DOOR ACTUATOR IAW MEL 52 10 1 2 0 1 DMP 52 10 1 2 0 1 CW PLACARDS INSTALLED CONTROL M 734022T/S L1 DOOR PER FIM 52-11-810-802. R/R'D FWD DOOR LOCK PIN RELEASE RELAY. (R2-5324) PER WDM 52-11-01. RAN L1 DOOR SEVERAL TIMES FROM INTERNAL & EXTERNAL SWITCH IAW AMM 52-10-01-700-801. NO FAULTS NOTED. THIS CLEARED M734622. PLACARD & DMP 52-10-1-2-0-1 REMOVED.