What was found
INSPECTION TYPE:ETOP*** SUPPLEMENTAL ETOPS ***R FUEL PUMP EICAS MSG AND PUMP SW LIGHT ILLUMINATED IN FLT. COMPLETE QRH PROCEDURE AND PUMP SW OFF. ASSIGNED TO MEL 28-22-1. C/W DMP 28-22-1. PLACARD INSTALLED.REPLACED RT FWD MAIN FUEL PUMP, REVERSED DMP 28-22-1. REPLACED PUMP IAW AMM 28-22-03-404, OPS CK GOOD M7427894, CLEARED PLACARD REMOVED.