As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY LIGHTING IN COURIER AREA REMAINS PARTIALLY ILLUMINATED WITH EMERGENCY LIGHT. TEST PASSED ANE WITHOUT INDICATION EAD. DEFERRED EMERGENCY LIGHTS PER MEL 33-50-4 DMP C/W PLACARD INSTALLED.R/R'D EMERGENCY BATTERY PWR SUPPLY PER MM 33-51-01 PG BLK 401. OPS CHECK PER MM 33-51-01-700-802 OPS CHECK NORMAL. M746660 CLOSED. PLACARD REMOVED.