What was found
NO EMERG DECL'D - NO EQUIP USED - LANDED UNEVENTFULLY, DUE TO EQUIP COOLING EICAS. PER MEL 36-11-4.L/H ISOLATION VALVE FAILED IN FLIGHT WILL BE SECURED OPEN.DMP PROCEEDURES PER MEL 36-11-4 COMPLIED WITH.DMI NO.M747173 PLACARD UINSTALED.CREW REPORTED VALVE L/H ISLN HAD TO BE SELECTED OFF IN FLT.REVERSED DMP 36-11-4. R/R'D LEFT WING ISOLATION VALVE PER MM 36-11-07-404-015. NO LEAKS NOTED OPS CHECKED GOOD. M747173 CLOSED. ESR IPC 36-11-57-01 S400.