What was found
INSPECTION TYPE:SEGMAIN CARGO DECK CROSSBEAM AT FRAME #51, BELOW FLOORBOARD PANEL #242ZJ AND 242EQ BETWEEN -Y450 AND N -Y953 IS CRACKED AND BUCKLEDRECEIVED NEW CROSSBEAM, LOCATED/DRILLED AND INSTALLED NEW PART IAW SRM 51-40-44 AND 51-40-21