What was found
INSPECTION TYPE:N/ACONNECTOR 4003VCA ON PANEL 923VU & SURRONDING AREA DAMAGED. ACCOMPLISHED EO A300 2450 80917A PARA 6 MAINTENANCE ACTIONS AND TRANSFERRED TO DEFERRAL #D749223 FERRY PERMIT 9022 ISSUED TO OPERATE ONE TIME FLIGHT FROM PHX TO SDF.REPLACED C/B PANEL 923VU, REF AWM 24-51-05, 24-54-02, & 25-52-04. REPLACED CONNECTOR 4003VCA AND RETERMINATED PINS A,B,C,D & G IAW SWPM 20-48-23. REVERSED MAINTENANCE ACTIONS CALLED OUT IN EO A300 2450 80917-A TO NORMAL CONFIGURATION, NO FUTHER DEFECTS NOTED. THIS CLEARS D749223.