As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:2CFWD LOWER CARGO FLOOR BEAM AT STA 6-70 & X= 57.50 IS CRACKED.REPAIRED CRACKED FWD LOWER CARGO FLOOR BEAM AT STA 6-70 & X= 57.50 IAW VT-SAA EA 011-5340-01-A9215 REV. IR AND UPS EO MD11-5310-80984-A. REF. FAA FORM 8100-9 SIGNED BY: STEPHEN KANG (AR-605677) DATED 07/12/2021. (MAJOR)