What was found
INSPECTION TYPE:NAL1 DR SEAL HAS MULTIPLE REPORTS OF HISSING /SQUEALING. SEAL WILL NOT SEAT PROPERLY IN LOWER FWD SEAL RETAINER OF L1 CREW ENTRY DOORR/R SEAL PER AMM 52-09-1-424-019. REMOVED SEAL RETAINER FOUND DAMAGED HOLES ROUTED TO UPS ENG REF SRM 51-40-02. CLEANED UP RIVET HOLES. REAMED ALL HOLES PER PRELIM EO B767-5210-81052-A #3. ACCOMPLISH HFEC PER NDTM PART 6 51-00-16 NO CRACKS NOTED AT THIS TIME. DOOR RE-INSTALLED PER MM 52-09-01.