What was found
INSPECTION TYPE:N/A** ATB ** UNEVENTFUL LANDING ILS RWY 15** HFL AND HFR SUCCESFUL TEST ON GND HFL AND HR COULD NOT TRANSMIT OR RECIEVE IN FLIGHTT/S PER FIM 23-11-21, OPS GOOD ON GROUND, ORDERED COUPLERS REQ#360693 JC 4835884 REMOVED AND REPLACED LH AND RH COUPLERS AND OPS CHECKS GOOD PER AMM 23-11-01, OK FOR SERVICE