As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:N/AL-1 DOOR EVAC SLIDE REMOTE PRESSURE PRESS TO TEST IND INOP. DEFERRED PER MEL 25-61-2 M 755635 ASSIGNED C/W DMP VERIFIED SLIDE PRESSURE GOOD L-1 DOOR PLACARD INSTALLED.REPLACED L1 EVAC SLIDE SW IAW AMM 25-61-00. OPS CK GOOD. AMM 25-61-06. THIS CLEARS DMI M755635. REMOVED PLACARD. REVERSED DMP 25-61.02.