Service difficulty report · Start Valve · Airbus A300F4622R

Difficulty date
September 29, 2021
Submitted
October 4, 2021
Operation
Air carrier
Aircraft
N163UP
Make and model
Airbus A300F4622R
Aircraft serial
0852
Aircraft time
20,841 hours, 12,418 cycles
Engine
Pwa PW4158
Part
Start Valve
Condition
Inoperative
Location
Powerplant
Stage of operation
TX
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

INSPECTION TYPE:N/A**SUPPLEMENTAL SDR** #1 ENGINE WOULD NOT START. NO ROTATION ON A OR B IGNITOR PACKS DISENGAGED BUT STILL NO ROTATION. DEFERRED #1 ENG START VALVE IAW MEL 80-13-01-1. DMP C/W.REPLACED #1 STARTER SHUTOFF VALVE PER AMM 80-13-02-0401. OPS CHECK GOOD PER IPC 80-11-00. THIS CLEARS M758114