As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:N/A** SUPPLEMENTAL SDR**ON PREFLIGHT FOUND L1 DOOR BOTTLE PRESSURE BELOW GREEN BAND. PLACARDED L1 DOOR INOP IAW MEL 52-10-3-1-2-1-1, M-763027 ASSIGNED. NOTE: DOOR MAYBE OPERATED FOR NORMAL INGRESS AND EGRESS ON THE GROUND. EXTENDED OVERWATER OPERATIONS PROHIBITED.SERVICED L1 ENTRY DOOR PNEUMATIC STORAGE AIR RESERVOIR REF AMM 12-25-04. THIS CLEARS M763027.