What was found
EICAS MSG FIRE/ OVERHEAT SYS ON FINAL APPROACH. RAN CHECKLIST, MESSAGE CLEARED. NOTED MSG CLEARED WITH CHECKLIST, PERFORMED FIRE DETECTION TEST REF AMM 26-11-00-715-001. RT ENG OH LPI ALREADY ON DEFERRAL ITEM M768813. (OPEN)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EICAS MSG FIRE/ OVERHEAT SYS ON FINAL APPROACH. RAN CHECKLIST, MESSAGE CLEARED. NOTED MSG CLEARED WITH CHECKLIST, PERFORMED FIRE DETECTION TEST REF AMM 26-11-00-715-001. RT ENG OH LPI ALREADY ON DEFERRAL ITEM M768813. (OPEN)