What was found
INSPECTION TYPE:SEG1LEFT HORIZONTAL STAB LWR SURFACE HAS 2 INCH DENT W/POSSIBLE DELAMINATION AT STA FS 83.482REPAIRED PANEL IAW B757 SRM 51-70-10-2R-4 PER SRM 55-10-1A-1, FIG 101, TABLE I
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SEG1LEFT HORIZONTAL STAB LWR SURFACE HAS 2 INCH DENT W/POSSIBLE DELAMINATION AT STA FS 83.482REPAIRED PANEL IAW B757 SRM 51-70-10-2R-4 PER SRM 55-10-1A-1, FIG 101, TABLE I