What was found
INSPECTION TYPE:NASUPPLEMENATAL ATB SDR FILED * NO EMERG DEC'D* CRUISE, FUEL CONFIG LIGHT/INDICATIONS & DROPPING FUEL QTY IN R MN TANK. FUEL QTY FLUCTUATED, THEN RETURN NRML. DEFERRED R/H MN TANK FUEL QTY IND SYS IAW MEL 28-41-1-1A. ASSIGNED CONTROL # M770895 & APPLIED PLACARD. DMP NOT COMPLIED WITH. ETOPS DWNGRD.FUEL QUANTITY INDICATING SYSTEM OPS CHECK GOOD. REF MM 28-41-00 THIS CLEARS M770895. PLACARD REMOVED.